• Self-Priming Double Suction Split Casing Centrifugal Water Drainage Pump
  • Self-Priming Double Suction Split Casing Centrifugal Water Drainage Pump
  • Self-Priming Double Suction Split Casing Centrifugal Water Drainage Pump
  • Self-Priming Double Suction Split Casing Centrifugal Water Drainage Pump
  • Self-Priming Double Suction Split Casing Centrifugal Water Drainage Pump
  • Self-Priming Double Suction Split Casing Centrifugal Water Drainage Pump

Self-Priming Double Suction Split Casing Centrifugal Water Drainage Pump

Max.Head: >150m
Max.Capacity: >400 L/min
Driving Type: Motor
Material: Cast Iron
Structure: Single-stage Pump
Assembly: Liquid Pumps
Customization:
Diamond Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Product Parameters
  • Product Advantage
  • Detailed Photos
  • Application
  • Company Profile
Overview

Basic Info.

Model NO.
ANS-SELF
Power
Electric
Start Up
Electric Pump
Type
Blade Pump
Application
Clarified Water Pump, Sewage Pump, Oil Transfer Pump, Chemical Pump
Industry
Air Conditioning Pump
Media
Water
Performance
No Leakage Pump
Theory
Centrifugal Pump
Solid Gerains
up to 80mg/L
Paint
Blue
OEM
Ok
Transport Package
Wooden-Case
Specification
DN80-1400
Trademark
TONGKE
Origin
China
HS Code
8413709990
Production Capacity
2000sets/Year

Product Description

Self Priming Horizontal split case double suction centrifugal  water pump

 

Product Description

Self-Priming Double Suction Split Casing Centrifugal Water Drainage Pump
Model ASN and ASNV pumps are single stage double suction split volute casing(case) centrifugal pump is the new generation of high performance single stage double suction centrifugal pump, mainly used for water plant, air conditioning, water recycling, heating systems, and high-rise building water supply, irrigation and drainage pumping stations, power plants, industrial water supply system, Fire systems, shipbuilding industry, and other places of fluid transmission.

1.Can control the pump unit automatically.

2.Both pump and self suction device use one shaft, no shaft power is increased.
3.Upon the self suction device, the pump s inlet is in a Vacuum status all the time and can extract air at any time.
4.Automatic exhaust and water suction is available in case of water cut-off in the inlet pipeline or requiring to start the pump often.
5.Two structures of single and double air rooms can be set up upon the size of the inlet pipeline and the pump, that means the quantity of air.
6.Not to change the construction of dual-suction pump.
The working principle of the pump refer to working principle drawing.

 

Product Parameters

Operation Parameter

Diameter DN 80-800MM
Capacity No more than 11600m³/h
Head No more than 200m
Liquid Temperature Up to 105ºC

 Recommended Material Configuration

Recommended Material Configuration (For reference only)
Item Clean water Drink water Sewage water Hot water Sea water
Case & Cover Cast iron HT250 SS304 Ductile iron QT500 Carbon steel Duplex SS 2205/Bronze/SS316L
Impeller Cast iron HT250 SS304 Ductile iron QT500 2Cr13 Duplex SS 2205/Bronze/SS316L
Wearing ring Cast iron HT250 SS304 Ductile iron QT500 2Cr13 Duplex SS 2205/Bronze/SS316L
Shaft SS420 SS420 40Cr 40Cr Duplex SS 2205
Shaft sleeve Carbon steel/SS SS304 SS304 SS304 Duplex SS 2205/Bronze/SS316L
Remarks:  Detailed material list will according to liquid and site conditions

Product Advantage

ANS series self priming single stage dual suction split casing powerful self suction centrifugal pump is a patent product developed in this for helping users to settle the difficult problem in the installation of pipeline engineering and equipped with a self suction device on the basis of the original dual suction pump to make the pump to have the exhaust and water-suction capacity.
AS of the existing centrifugal pump unit, the user has to do one of the three jobs below when to get the pump suck and start working:
 
1.mount a foot valve on the water suction pool of the inlet pipeline and close it before starting the pump, then open it when the pump is full of water inside and the air inside is completely exhausted. Under-liquid installation of the foot valve makes overhaul very inconvenient in case of a failure.
 
2.equip the pump unit with a vacuum pump to lead the water in the suction pool into the pump. Different norms of the pump unit need different norms of the vacuum pump, requiring a cost not low and thus increasing the engineering cost.
 
3.mount the pump unit under the sucked in liquid surface, i.e. Inverse pumping, that means the basis of the pump room must be below the ground, i.e. digging hole underground, this makes the engineering cost greatly increased. While the powerful self-suction centrifugal pump can make it satisfied for a user to have the pump normally pumping without use of any of the three ways above-mentioned!
Similar to the common dual suction pump, this series pump is also suitable for a water works, air-conditioning water circulating system, water supply of buildings, irrigation, water draining pump station, electric station, industrial water supply system, Shipping industry etc.
 
To transport pure water or the Liquid of both physical and chemical natures similar to Pure water.

 

Detailed Photos

Self-Priming Double Suction Split Casing Centrifugal Water Drainage PumpSelf-Priming Double Suction Split Casing Centrifugal Water Drainage Pump

Application


Municipal, construction, ports
Chemical industry, paper making, paper pulp industry
∧ Mining and metallurgy;
∧ Fire control
∧ Environmental protection


Self-Priming Double Suction Split Casing Centrifugal Water Drainage Pump

√ NOTE before order
Parameters necessary to be submitted at order Double Suction Split casing Centrifugal water Pump with motor

1. Pump model and the flow, head (including the system loss), NPSHr at the point of the desired working condition.

2. Type of shaft seal (must be noted either mechanical or packing seal and, if not, delivery of the mechanical seal structure will be made).

3. Moving direction of the pump (must be noted in case of a CCW installation and, if not, delivery of a clockwise installation will be made).

4. Parameters of the motor (Y series motor of IP44 is generally used as the low-voltage motor with a power <200KW and, when to use a high voltage one, please note its voltage, protective rating, insulation class, way of cooling, power, number of polarity and manufacturer).

5. The materials of pump casing, impeller, shaft etc. parts. (delivery with the standard allocation will be made if without being noted).

6. Medium temperature (delivery upon a constant-temperature medium will be made if without being noted).

7. When the medium to be transported is corrosive or contains solid grains, please note the features of it.

 

Company Profile

Self-Priming Double Suction Split Casing Centrifugal Water Drainage PumpSelf-Priming Double Suction Split Casing Centrifugal Water Drainage PumpSelf-Priming Double Suction Split Casing Centrifugal Water Drainage PumpSelf-Priming Double Suction Split Casing Centrifugal Water Drainage PumpSelf-Priming Double Suction Split Casing Centrifugal Water Drainage PumpSelf-Priming Double Suction Split Casing Centrifugal Water Drainage Pump

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001