• Split Casing Double Suction Type Nfpa UL FM Fire Pump
  • Split Casing Double Suction Type Nfpa UL FM Fire Pump
  • Split Casing Double Suction Type Nfpa UL FM Fire Pump
  • Split Casing Double Suction Type Nfpa UL FM Fire Pump
  • Split Casing Double Suction Type Nfpa UL FM Fire Pump
  • Split Casing Double Suction Type Nfpa UL FM Fire Pump

Split Casing Double Suction Type Nfpa UL FM Fire Pump

After-sales Service: Installation and Debugging, Spare Parts, Training
Warranty: 12 Months
Max.Head: >150m
Max.Capacity: >400 L/min
Driving Type: Motor
Material: Cast Iron,Stainless Steel, Carbon Steel etc
Customization:
Diamond Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory
  • Overview
  • Product Description
  • Our Advantages
  • FAQ
  • Company Profile
Overview

Basic Info.

Model NO.
ANS
Structure
Single-stage Pump
Assembly
Liquid Pumps
Power
Electric
Start Up
Electric Pump
Type
Fire Pump
Application
Fire-Fighting
Industry
Fire Fighting
Media
Water
Performance
Safe and High Efficency
Theory
Centrifugal Pump
Flange
ASME, DIN, GB
OEM
Ok
UL Listed
Yes
Certificate
ISO UL CE
Transport Package
Wooden-Case
Specification
Fire
Trademark
TONGKE
Origin
China
HS Code
8413709990
Production Capacity
3000 Set/Year

Product Description

Product Description
Model No:XBC-ANS
Precision balancing of all factors in the design of ANS horizontal split case fire pump provide mechanical dependability, efficient operation and minimal maintenance. Simplicity of design ensures long efficient unit life, reduced maintenance costs and minimum power consumption.
Split case fire pumps are specifically designed and tested for fire service application around the world including: Office buildings, hospitals, airports, manufacturing facilities, warehouses, power stations, oil and gas industry, schools.

 
Split Casing Double Suction Type Nfpa UL FM Fire Pump
Our Advantages

Quality Assurance Safety
Split Casing Double Suction Type Nfpa UL FM Fire Pump
First-Class international technical standards
Horizontal Split Case (ANS) pumps are given their name due to the "split" design of the casing, where the casing cover can be lifted off of the pump to expose the internal components. These components include the impeller, bearings, pump shaft, and so on. ANS pumps have two bearings, located on either side of the impeller, which are useful to withstand the large amount of vibration and thrust forces often caused by water turbulence in the suction piping. The pump casings are often designed to handle higher working pressures, and are often heavier. The durability of the ANS design allows the pump to be used for very large water flows - often in excess of 5000 GPM. It should be noted that an ANS pump is not always mounted horizontally, it is possible to have the same durability design features and have the pump designed to be mounted vertically.

Split Casing Pump Advantages:

  • Single stage, medium pressure double inlet centrifugal pump with two flanged bearing frame, suitable for flexible coupling to electric motor or internal combustion engine as a driver;
  • Ample dimensioned shaft guided through roller bearings and hardened shaft sleeve;
  • Fully-enclosed single piece casting, double inlet impeller practically doesn't produce any axial trust;
  • High operating reliability due to maintenance and service parts;
  • Spiral housing axially spitted means easy maintenance without pipe disconnection.
 
Why choose us?
  • Specialized production Manufactory for fire Pump
  • Focus on technological innovation, Over Industry leading level
  • Good experience at Domestic and oversea market
  • Carefully paint  for Good appearance
  • Years of International service standards, Engineer one-to-one service
  • Make to order, According to site requirements and working condition of the production



UL listed fire fighting pumps date can be choosed
Pump Model 
(split casing pump)
Rated Capacity
(GPM)
Inlet×Outlet
(INCH)
Rated Net Pressure Range (PSI) Approx Speed
(RPM)
Max working Pressure (PSI)
80-350 300 5×3 129-221 2950 290.00
80-350 400 5×3 127-219 2950 290.00
100-400 500 6×4 225-288 2950 350.00
80-280(I) 500 5×3 86-153 2950 200.00
100-320 500 6×4 115-202 2950 230.00
100-400 750 6×4 221-283 2950 350.00
100-320 750 6×4 111-197 2950 230.00
125-380 750 8×5 52-75 1480 200.00
125-480 1000 8×5 64-84 1480 200.00
125-300 1000 8×5 98-144 2950 200.00
125-380 1000 8×5 46.5-72.5 1480 200.00
150-570 1000 8×6 124-153 1480 290.00
125-480 1250 8×5 61-79 1480 200.00
150-350 1250 8×6 45-65 1480 200.00
125-300 1250 8×5 94-141 2950 200.00
150-570 1250 8×6 121-149 1480 290.00
150-350 1500 8×6 39-63 1480 200.00
125-300 1500 8×5 84-138 2950 200.00
200-530 1500 10×8 98-167 1480 290.00
250-470 2000 14×10 47-81 1480 290.00
200-530 2000 10×8 94-140 1480 290.00
250-610 2000 14×10 98-155 1480 290.00
250-610 2500 14×10 92-148 1480 290.00

Applications for UL listed fire fighting pumps
 split casing centrifugal pump with motor for fire fighting
Δ Fixed fire-fighting systems of industrial and civil buildings
Δ  Fire hydrant fire-fighting system
Δ  Automatic sprinkler fire-fighting system
Δ  Spraying fire-fighting system

Split Casing Double Suction Type Nfpa UL FM Fire Pump


UL listed fire fighting pumps Structural Features & Performance Advantages

 √  Profession al design software and development system, and advanced CFD three-mode analysis;
√  Compact structure, streamline appearance, good stability and ease of installation;
√  Steady operation, great cavitations resistance performance and high efficiency;
√  Domestically-pioneering sleeve-less patented technology ensures the pump's reliability, and maximizes the ease of maintenance and care for users.

Split Casing Double Suction Type Nfpa UL FM Fire Pump



Fire Protection
You have decided to reduce the risk of fire damage to your facility by installing a UL, ULC listed fire pump system. Your next decision is which system to purchase.
You want a fire pump that is proven in installations worldwide. Manufactured by an professional with vast experience in the fire protection field. You want complete service to field start-up. You want a TONGKE Pump.

Providing Pumping Solutions TONGKE Can Fulfill Your Requirements:
  • Complete in-house fabrication capabilities
  • Mechanical-run test capabilities with customer furnished equipment for all NFPA standards
  • Horizontal models for capacities to 2,500 gpm
  • Vertical models for capacities to 5,000 gpm
  • In-line models for capacities to 1,500 gpm
  • End suction models for capacities to 1,500 gpm
  • Drives: electric motor or diesel engine
  • Basic units and packaged systems.

Fire Pump Units & Packaged Systems
Electric Motor Drive and Diesel Engine Drive fire pumps can be furnished for any combination of pumps, drives, controls and accessories for listed and approved and NONlisted fire service applications. Packaged units and systems lower fire pump installation costs and offer these

Accessories
To meet the recommendations of the standards of the National Fire Protection Association as published in their Pamphlet 20, current edition, certain accessories are required for all fire pump installations. They will vary, however, to fit the needs of each individual installation and the requirements of the local insurance authorities. Tongke Pump provides a wide range of fire pump fittings which include: concentric discharge increaser, casing relief valve, eccentric suction reducer, increasing discharge tee, overflow cone, hose valve head, hose valves, hose valve caps and chains, suction and discharge gauges, relief valve, automatic air release valve, flow
meter, and ball drip valve. No matter what the requirements, Sterling has a complete line of accessories available and can satisfy the requirements of each installation.
The charts reproduced below graphically illustrate the many accessories as well as the optional drives that are available with all Tongke fire pumps and packaged systems.


 
FAQ

Q. What makes a fire pump different from other kinds of pumps?


A.  First, they meet the stringent requirements of NFPA Pamphlet 20, Underwriters Laboratories and Factory Mutual Research Corporation for reliability and unfailing service under the most difficult and demanding circumstances. This fact alone should speak well for TKFLO's product quality and premium design features. Fire pumps are required to produce specific flow rates (GPM) and pressures of 40 PSI or greater. Further, the above mentioned agencies advise that the pumps should produce at least 65% of that pressure at 150% of the rated flow -- and all the while operating at a 15 foot lift condition. The performance curves must be such that the shut-off head, or "churn," is from 101% to 140% of the rated head, depending upon the agency's definition of the term. TKFLO's fire pumps are not offered for fire pump service unless they meet all agencies' requirements.
Beyond performance characteristics, TKFLO fire pumps are carefully scrutinized by both NFPA and F.M. for reliability and long life through analysis of their design and construction. Casing integrity, for example, must be suitable to withstand a hydrostatic test of three times the maximum operating pressure without bursting! TKFLO's compact and well-engineered design allows us to satisfy this specification with many of our 410 and 420 models. Engineering calculations for bearing life, bolt stress, shaft deflection, and shear stress must also be submitted to NFPA . and F.M. and must fall within conservative limits to ensure utmost reliability. Finally, after all the preliminary requirements have been met, the pump is ready for final certification testing to be witnessed by representatives from U.L. and F.M. Performance tests will require that several impeller diameters will be demonstrated satisfactorily, including the minimum and maximum, and several in between.

Q. What is the typical lead time for a fire pump?
A. Typical lead times run 5-8 weeks from release of an order. Call us for details.

Q. What is the easiest way of determining pump rotation?
A. For a horizontal split-case fire pump, if you are sitting on the motor facing the fire pump, from this vantage point a pump is right-hand, or clock-wise, if the suction is coming from the right and the discharge is heading toward the left. The opposite is true for left-handed, or counter-clockwise rotation. The key is the vantage point when discussing this topic. Make sure both parties are viewing the pump casing from the same side.

Q. How are engines and motors sized for fire pumps?
A. Motors and engines supplied with TKFLO fire pumps are sized according to U.L., F.M. and NFPA 20 (2013), and are designed to operate on any point of the fire pump curve without exceeding the motor nameplate service factor, or engine size. Do not be fooled into thinking that the motors are sized only to 150% of nameplate capacity. It is not uncommon for fire pumps to operate well beyond 150% of rated capacity (for example, if there is an open hydrant or broken pipe downstream).
For more specifics, please refer to NFPA 20 (2013) paragraph 4.7.6, UL-448 paragraph 24.8, and Factory Mutual's Approval Standard for Split Case Fire Pumps, Class 1311, paragraph 4.1.2. All motors and engines supplied with TKFLO fire pumps are sized to the true intent of NFPA 20, U.L. , and Factory Mutual.
Since fire pump motors are not expected to be running continuously, they are often sized to take advantage of a 1.15 motor service factor. So unlike domestic water or HVAC pump applications, a fire pump motor is not always sized "non-overloading" across the curve. As long as you do not exceed the motor 1.15 service factor, it is allowed. An exception to this is when a variable speed inverter duty electric motor is used.

Q. Can I use a flow meter loop as a substitute for a test header?
A. A flow meter loop is often practical where flowing excessive water through standard U.L. Playpipe nozzles are inconvenient; however, when using a closed flow meter loop around a fire pump, you may be testing the pumps hydraulic performance, but you are NOT testing the water supply, which is a critical component of the fire pump system. If there is an obstruction to the water supply, this will not be evident with a flow meter loop, but will certainly be exposed by testing a fire pump with hoses and Playpipes. On an initial start-up of a fire pump system, we always insist on flowing water through the system to ensure the integrity of the entire system.
If a flow meter loop is returned back to the water supply -- such as an above-ground water tank -- then under that arrangement you will be able to test both the fire pump and the water supply. Just make sure that your flow meter is properly calibrated.

Q. Do I need to worry about NPSH in fire pump applications?
A. Rarely. NPSH (net positive suction head) is an important consideration in industrial applications, such as boiler feed or hot water pumps. With fire pumps, however, you are dealing with cold water, which uses all of atmospheric pressure to your advantage. Fire pumps need a "flooded suction," where the water arrives to the pump impeller through gravity. You need this to guarantee a pump prime 100% of the time, so that when you have a fire, your pump operates! It is certainly possible to install a fire pump with a foot valve or some artificial means for priming, but there is no way to guarantee 100% that the pump will function properly when called on to operate. In many split-case double suction pumps, it only takes approximately 3% of air in the pump casing to render the pump inoperable. For that reason, you will not find a fire pump manufacturer willing to risk selling a fire pump for any installation that does not guarantee a "flooded suction" to the fire pump at all times.

Q. When will you answer more questions on this FAQ page?
A. We will add them as issues arise, but feel free to contact us with your questions!

 
Company Profile

 

Split Casing Double Suction Type Nfpa UL FM Fire PumpSplit Casing Double Suction Type Nfpa UL FM Fire PumpSplit Casing Double Suction Type Nfpa UL FM Fire PumpSplit Casing Double Suction Type Nfpa UL FM Fire PumpSplit Casing Double Suction Type Nfpa UL FM Fire Pump
Your call and mail is welcome at any time
Contact Mr Seth Chen
Telephone 0086-13817768896

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory
Type of Ownership
Limited Company
Management System Certification
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001