Providing Pumping Solutions TONGKE Can Fulfill Your Requirements:
- Complete in-house fabrication capabilities
- Mechanical-run test capabilities with customer furnished equipment for all NFPA standards
- Horizontal models for capacities to 2,500 gpm
- Vertical models for capacities to 5,000 gpm
- In-line models for capacities to 1,500 gpm
- End suction models for capacities to 1,500 gpm
- Drives: electric motor or diesel engine
- Basic units and packaged systems.
Product Description
Products Description
Precision balancing of all factors in the design of ASN horizontal split case fire pump provide mechanical dependability, efficient operation and minimal maintenance. Simplicity of design ensures long efficient unit life, reduced maintenance costs and minimum power consumption.Split case fire pumps are specifically designed and tested for fire service application around the world including: Office buildings, hospitals, airports, manufacturing facilities, warehouses, power stations, oil and gas industry, schools.
GPM 300-2500 ASN series NFPA20/UL listed double suction split case centrifugal fire fighting pump
Split case centrifugal fire fighting pump with electric motor
Split case centrifugal fire fighting pump with diesel engine
With NFPA 20 jockey pump and control system
Systems
TONGKE Fire Pump installations (UL approved ,Follow NFPA 20 and CCCF ) deliver superior fire protection to facilities worldwide. TONGKE Pump has been offering complete service, from engineering assistance to in house fabrication to field start-up. Products are designed from a broad selection of pumps, drives, controls, base plates and accessories. Pump choices include horizontal, in-line and end suction centrifugal fire pumps as well as vertical turbine pumps.
Both horizontal and vertical models provide capabilities up to 5,000 gpm. End suction models deliver capacities to 2,000 gpm. In-line units can produce 1,500 gpm. Head ranges from 100 ft to 1,600 ft with as much as 500 meters. Pumps are powered with electric motors, diesel engines or steam turbines. Standard fire pumps are Ductile cast iron with bronze fittings. TONGKE supply the fittings and accessories recommended by the NFPA 20.
Application
Applications vary from small, basic electric motor driven to diesel engine driven, packaged systems. Standard units are designed to handle fresh water, but special materials are available for sea water and special liquid applications.
The TONGKE Fire Pumps give superior performance in Agriculture, General Industry, Building Trade, Power Industry, Fire Protection, Municipal, and Process applications.
Features
State of the art engineered systems arrive ready to install. Pump, driver and controller are mounted on a common base.All engineered systems have complete, interconnected wiring. Preconstruction eliminates costly, complex installation problems. In-house fabrication gives TONGKE Pump the ability to customize a system and assume complete unit responsibility, which means the customer has only one supplier to contact if there are questions. All pump package system meet the requirements of UL LIST, NFPA20, and CCCF. TONGKE Pump extensive distribution system provides worldwide technical and commercial support with qualified personnel in most major Asia and international .
ASN split case fire fighting pump
Horizontal split casing centrifugal pumps complies with NFPA 20 and UL listed application requirements and with appropriate fittings for providing water supply to fire protection systems in buildings, factories plants and yards.
Parameters
Capacity |
300 to 2500GPM(68 TO 567 M3/HR |
Head |
90 TO 650 FEET(26 TO 198 meters) |
Pressure |
Up to 650 psi(45 kg/cm 2,4483 kps) |
House Power |
Up hp 800 hp (597 kw) |
Divers |
Horizontal electric motors, diesel engines |
Liquid type |
Water or sea water |
Temperature |
Ambient within the limits for satisfactory equipment operation |
Material of construction |
Cast iron, Stainless steel, Ni-Al Bronze, Duplex stainless steel |
Horizontal Split Casing Centrifugal Fire Pump Section View/Detail
Performance Range of Horizontal Split Case Pump
UL listed fire fighting pumps date can be choosed
Pump Model (split casing pump) |
Rated Capacity
(GPM) |
Inlet×Outlet
(INCH) |
Rated Net Pressure Range (PSI) |
Approx Speed
(RPM) |
Max working Pressure (PSI) |
80-350 |
300 |
5×3 |
129-221 |
2950 |
290.00 |
80-350 |
400 |
5×3 |
127-219 |
2950 |
290.00 |
100-400 |
500 |
6×4 |
225-288 |
2950 |
350.00 |
80-280(I) |
500 |
5×3 |
86-153 |
2950 |
200.00 |
100-320 |
500 |
6×4 |
115-202 |
2950 |
230.00 |
100-400 |
750 |
6×4 |
221-283 |
2950 |
350.00 |
100-320 |
750 |
6×4 |
111-197 |
2950 |
230.00 |
125-380 |
750 |
8×5 |
52-75 |
1480 |
200.00 |
125-480 |
1000 |
8×5 |
64-84 |
1480 |
200.00 |
125-300 |
1000 |
8×5 |
98-144 |
2950 |
200.00 |
125-380 |
1000 |
8×5 |
46.5-72.5 |
1480 |
200.00 |
150-570 |
1000 |
8×6 |
124-153 |
1480 |
290.00 |
125-480 |
1250 |
8×5 |
61-79 |
1480 |
200.00 |
150-350 |
1250 |
8×6 |
45-65 |
1480 |
200.00 |
125-300 |
1250 |
8×5 |
94-141 |
2950 |
200.00 |
150-570 |
1250 |
8×6 |
121-149 |
1480 |
290.00 |
150-350 |
1500 |
8×6 |
39-63 |
1480 |
200.00 |
125-300 |
1500 |
8×5 |
84-138 |
2950 |
200.00 |
200-530 |
1500 |
10×8 |
98-167 |
1480 |
290.00 |
250-470 |
2000 |
14×10 |
47-81 |
1480 |
290.00 |
200-530 |
2000 |
10×8 |
94-140 |
1480 |
290.00 |
250-610 |
2000 |
14×10 |
98-155 |
1480 |
290.00 |
250-610 |
2500 |
14×10 |
92-148 |
1480 |
290.00 |
UL listed NFPA 20 Split casing centrifugal fire fighting pump with electric motor
Horizontal multistage centrifugal fire pumps with appropriate fittings for providing water supply to fire protection systems in buildings, plants and yards.
NFPA 20 Diesel engine drive Split casing double suction centrifugal fire water pump set
Horizontal end suction centrifugal fire pumps with appropriate fittings for providing water supply to fire protection systems in buildings, plants and yards.
Multistage Centrifugal High Pressure Stainless Steel Jockey Pump Fire Water Pump
A jockey pump is a pump connected to a fire sprinkler system and is intended to maintain pressure in a fire protection piping system to an artificially high level so that the operation of a single fire sprinkler will cause a pressure drop which will be sensed by the fire pump automatic controller, causing the fire pump to start. The jockey pump is essentially a portion of the fire pump's control system.
Parameters
Outlet Diameter |
25-150 mm |
Capacity |
18-360 m3/h |
Pressure |
0.3-2.5MPa |
Medium temperature |
-10 ~ 80°C |
Material |
Casing/impeller: cast iron, stainless steel, copper, bronze, Shaft: carbon steel 45#,stainless steel |
Seal |
Bergmann mechanical seal |
Bearing |
SKF/NTN/NSK |
Motor |
High quality motor or UL motor |
Fire Protection
You have decided to reduce the risk of fire damage to your facility by installing a UL, ULC listed fire pump system. Your next decision is which system to purchase.
You want a fire pump that is proven in installations worldwide. Manufactured by an professional with vast experience in the fire protection field. You want complete service to field start-up. You want a TONGKE Pump.
Fire Pump Units & Packaged Systems
Electric Motor Drive and Diesel Engine Drive fire pumps can be furnished for any combination of pumps, drives, controls and accessories for listed and approved and NON Listed fire service applications. Packaged units and systems lower fire pump installation costs and offer these.
Accessories
To meet the recommendations of the standards of the National Fire Protection Association as published in their Pamphlet 20, current edition, certain accessories are required for all fire pump installations. They will vary, however, to fit the needs of each individual installation and the requirements of the local insurance authorities. Tongke Pump provides a wide range of fire pump fittings which include: concentric discharge increaser, casing relief valve, eccentric suction reducer, increasing discharge tee, overflow cone, hose valve head, hose valves, hose valve caps and chains, suction and discharge gauges, relief valve, automatic air release valve, flow
meter, and ball drip valve. No matter what the requirements, Sterling has a complete line of accessories available and can satisfy the requirements of each installation.
The charts reproduced below graphically illustrate the many accessories as well as the optional drives that are available with all Tongke fire pumps and packaged systems.
UL listed fire fighting pumps
Structural Features & Performance Advantages
√ Profession al design software and development system, and advanced CFD three-mode analysis;
√ Compact structure, streamline appearance, good stability and ease of installation;
√ Steady operation, great cavitations resistance performance and high efficiency;
√ Domestically-pioneering sleeve-less patented technology ensures the pump's reliability, and maximizes the ease of maintenance and care for users.
Why choose us?
• Specialized production Manufactory for fire Pump
• Focus on technological innovation, Over Industry leading level
• Good experience at Domestic and oversea market
• Carefully paint for Good appearance
• Years of International service standards, Engineer one-to-one service
• Make to order, According to site requirements and working condition of the production
More details about our UL listed fire fighting pumps please contact Tongke.
https://tkflow.en.made-in-china.com/contact-info.html
Packaging & Shipping
Packing & Shipping
Packaging: Conventional Packaging suitable for by sea or long distance transportation.
Shipping: 20-45 working days after receiving the deposit of the devices
Company Profile
Company information:
Shanghai Tongke flow technology Co., Ltd. is a professional technology and energy-saving products R & D, product the high efficiency pump , vertical turbine pump , self priming pump ,movable pump station , and energy saving service of the national high-tech enterprises. Belong to Tongji University High-Tech Park and there is three industrial bases located in Shanghai, Dalian and Jiangsu.
Quality guarantee
Shanghai Tongke flow technology Co., Ltd. always foucs on the Technology design, The company's gist is different operation and the goal is the high-quality, high-performance products. We strive to become a trustworthy professional automobileseat cushion company. We passed the TUV registed ISO 9001 and products is passed SGS inspection.
Services:
Vertical split casing centrifugal pump with motor for fire fighting
1.one year guarantee for whole machine except for wear parts;
2.24 hours technical support by email;
3.calling service;
4.user manual available;
5.reminding for the service life of the wearing parts;
6.installation guide for clients from both China and abroad;
7.maintance and replacement service;
8.whole process training and guidance from our technicians.
FAQ
Q. What makes a fire pump different from other kinds of pumps?
A. First, they meet the stringent requirements of NFPA Pamphlet 20, Underwriters Laboratories and Factory Mutual Research Corporation for reliability and unfailing service under the most difficult and demanding circumstances. This fact alone should speak well for TKFLO's product quality and premium design features. Fire pumps are required to produce specific flow rates (GPM) and pressures of 40 PSI or greater. Further, the above mentioned agencies advise that the pumps should produce at least 65% of that pressure at 150% of the rated flow -- and all the while operating at a 15 foot lift condition. The performance curves must be such that the shut-off head, or "churn," is from 101% to 140% of the rated head, depending upon the agency's definition of the term. TKFLO's fire pumps are not offered for fire pump service unless they meet all agencies' requirements.
Beyond performance characteristics, TKFLO fire pumps are carefully scrutinized by both NFPA and F.M. for reliability and long life through analysis of their design and construction. Casing integrity, for example, must be suitable to withstand a hydrostatic test of three times the maximum operating pressure without bursting! TKFLO's compact and well-engineered design allows us to satisfy this specification with many of our 410 and 420 models. Engineering calculations for bearing life, bolt stress, shaft deflection, and shear stress must also be submitted to NFPA . and F.M. and must fall within conservative limits to ensure utmost reliability. Finally, after all the preliminary requirements have been met, the pump is ready for final certification testing to be witnessed by representatives from U.L. and F.M. Performance tests will require that several impeller diameters will be demonstrated satisfactorily, including the minimum and maximum, and several in between.
Q. What is the typical lead time for a fire pump?
A. Typical lead times run 5-8 weeks from release of an order. Call us for details.
Q. What is the easiest way of determining pump rotation?
A. For a horizontal split-case fire pump, if you are sitting on the motor facing the fire pump, from this vantage point a pump is right-hand, or clock-wise, if the suction is coming from the right and the discharge is heading toward the left. The opposite is true for left-handed, or counter-clockwise rotation. The key is the vantage point when discussing this topic. Make sure both parties are viewing the pump casing from the same side.
Q. How are engines and motors sized for fire pumps?
A. Motors and engines supplied with TKFLO fire pumps are sized according to U.L., F.M. and NFPA 20 (2013), and are designed to operate on any point of the fire pump curve without exceeding the motor nameplate service factor, or engine size. Do not be fooled into thinking that the motors are sized only to 150% of nameplate capacity. It is not uncommon for fire pumps to operate well beyond 150% of rated capacity (for example, if there is an open hydrant or broken pipe downstream).
For more specifics, please refer to NFPA 20 (2013) paragraph 4.7.6, UL-448 paragraph 24.8, and Factory Mutual's Approval Standard for Split Case Fire Pumps, Class 1311, paragraph 4.1.2. All motors and engines supplied with TKFLO fire pumps are sized to the true intent of NFPA 20, U.L. , and Factory Mutual.
Since fire pump motors are not expected to be running continuously, they are often sized to take advantage of a 1.15 motor service factor. So unlike domestic water or HVAC pump applications, a fire pump motor is not always sized "non-overloading" across the curve. As long as you do not exceed the motor 1.15 service factor, it is allowed. An exception to this is when a variable speed inverter duty electric motor is used.
Q. Can I use a flow meter loop as a substitute for a test header?
A. A flow meter loop is often practical where flowing excessive water through standard U.L. Playpipe nozzles are inconvenient; however, when using a closed flow meter loop around a fire pump, you may be testing the pumps hydraulic performance, but you are NOT testing the water supply, which is a critical component of the fire pump system. If there is an obstruction to the water supply, this will not be evident with a flow meter loop, but will certainly be exposed by testing a fire pump with hoses and Playpipes. On an initial start-up of a fire pump system, we always insist on flowing water through the system to ensure the integrity of the entire system.
If a flow meter loop is returned back to the water supply -- such as an above-ground water tank -- then under that arrangement you will be able to test both the fire pump and the water supply. Just make sure that your flow meter is properly calibrated.
Q. Do I need to worry about NPSH in fire pump applications?
A. Rarely. NPSH (net positive suction head) is an important consideration in industrial applications, such as boiler feed or hot water pumps. With fire pumps, however, you are dealing with cold water, which uses all of atmospheric pressure to your advantage. Fire pumps need a "flooded suction," where the water arrives to the pump impeller through gravity. You need this to guarantee a pump prime 100% of the time, so that when you have a fire, your pump operates! It is certainly possible to install a fire pump with a foot valve or some artificial means for priming, but there is no way to guarantee 100% that the pump will function properly when called on to operate. In many split-case double suction pumps, it only takes approximately 3% of air in the pump casing to render the pump inoperable. For that reason, you will not find a fire pump manufacturer willing to risk selling a fire pump for any installation that does not guarantee a "flooded suction" to the fire pump at all times.
Q. When will you answer more questions on this FAQ page?
A. We will add them as issues arise, but feel free to contact us with your questions!
Your call and mail is welcome at any time
Contact |
Mr Seth Chen |
Telephone |
0086-13817768896 |